Installing the NH3 Clog Monitor The NH3 blockage display is a system that supplies cultivators with the capacity to identify stopped up lines or various other obstructions that can lead to uneven distribution of NH3 to the field. The system makes use of magnetic picking up technology installed behind the liquid application to discover blockages and then develops a signal alert which is learnt through the control board right from the tractor taxi and also presented on the front-panel LCD with making use of the controller (see alternatives listed below). The screen system can be set up in 3 ways: Standard wired control panel, iPad or Android wireless systems, or an ISOBUS version is readily available (qualification pending). It enables cultivators to know their liquid or anhydrous NH3 flow prices in real time from the tractor taxicab and also is offered with 2 or 4 rows of sensing units. This system can be made use of in conjunction with CDS-John Blue’s LMBS or Micro-Trak NH3 kits, depending on the model being made use of and also what alternatives are acquired. It enables farmers to see a visual display screen as well as listen to an audible alarm on the control panel and then have the option to “Pause” to record issue rows for examination later when the driver has the possibility to quit. Unlike various other systems that need an operator to drive as well as reverse repetitively to see the back stress gauges, this system is installed directly on the delivery hose pipe( s) as well as can be seen from the tractor cab. The system is made to instantly and repeatedly scan to identify a blockage and after that develop a signal alert to be heard from the control panel and also presented on the front-panel LCD with a numerical indication of which row number is obstructed. Installing the Chillgard NH3 Screen is a rather basic process. The system must be unpacked, mounted and also attached according to the layout in Chapter 1, “Set-up.”. As soon as set up, the unit has to be calibrated to make sure that it is working effectively. Calibration should be carried out often to make sure that the gas sensing unit is functioning correctly and the screen indicates the proper focus of the gas for which it was calibrated. Calibration can be carried out by using a calibration gas to the sensor, after that making use of the display to establish the correct concentration of the gas for which it has been adjusted. Then, the user might use the exact same calibration gas to the unit again to validate that the cal- bration achieved success. Throughout the calibration, it is very important to check out all of the instructions very carefully and familiarize yourself with every one of the parts. This will certainly help with the ease of calibration. Likewise, it is excellent technique to connect all the parts before attempting the actual calibration. To prevent electric noise issues, do not run AC lines from the relays in the same channel or cable tray as the DC Signal lines. This can cause electrical interference in the location and protect against the unit from operating effectively. The Chillgard NH3 Gas Screen is made with interior relays, which are turned on when the device finds an alarm condition. The relays can be handicapped or configured to de-energize when a fault problem is detected and also can be transformed or validated via the Ultima Controller.